CFNXF - 140-2452 SAFETY ORANGE, SUPER ACRYLIC (SUPP DATA)
- MSDS: CFNXF
- Manufacturer: SHERWIN WILLIAMS CO
- Product Name: 140-2452 SAFETY ORANGE, SUPER ACRYLIC (SUPP DATA)
- National Stock Number: 8010-00N045019
Product Identification
Product ID:140-2452 SAFETY ORANGE, SUPER ACRYLIC (SUPP DATA)
MSDS Date:11/01/1995
FSC:8010
NIIN:00N045019
MSDS Number: CFNXF
Responsible Party
CLEVELAND, OH 44115
US
Emergency Phone: 216-566-2917
Info Phone: 216-566-2902
Cage: 54636
Contractor
Telephone: 800-251-2486/216-566-2242
Cage: 54636
Ingredients
IMMEDIATELY APPARENT. OBTAIN MEDICAL ATTENTION.
RTECS: 9999999ZZ
INHALING CONTENTS CAN BE HARMFUL/FATAL.
RTECS: 9999999ZZ
CALIFORNIA TO CAUSE CANCER & BIRTH DEFECTS/OTHER
RTECS: 9999999ZZ
NAVY LIST OF OCCUP CHEM REPRO HAZS. SEEK
RTECS: 9999999ZZ
HAZARD LIST INFORMATION & SAFE HANDLING & EXPOSURE
RTECS: 9999999ZZ
PROCS. CONTENTS UNDER PRESS. DO NOT PUNCTURE,
RTECS: 9999999ZZ
RADIATORS, STOVES, HOT WATER & OTHER HEAT SOURCES
RTECS: 9999999ZZ
KEEP OUT OF REACH OF CHILDREN. USE ONLY W/ADEQ VENT.
RTECS: 9999999ZZ
EYES. THESE COATINGS MAY CONTAIN MATLS CLASSIFIED AS
RTECS: 9999999ZZ
LEVELS ONLY DURING SANDING/ABRADING OF DRIED FILM.
RTECS: 9999999ZZ
NUISANCE DUSTS ARE ACGIH TLV 10 MG/M3 (TDUST), OSHA
RTECS: 9999999ZZ
ADDN OF REDUCERS/OTHER ADDITIVES TO THESE PRODS MAY
RTECS: 9999999ZZ
760.
CAS: 74-98-6
RTECS: TX2275000
Fraction By Weight: 14%
OSHA PEL 1000 PPM
ACGIH TLV: ASPHYXIANT
760.
CAS: 106-97-8
RTECS: EJ4200000
Fraction By Weight: 14%
OSHA PEL 800 PPM
ACGIH TLV: 800 PPM
22.
CAS: 108-88-3
RTECS: XS5250000
Fraction By Weight: 40%
OSHA PEL 200 PPM
ACGIH TLV: 50 PPM, S
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
7.1.
CAS: 100-41-4
RTECS: DA0700000
Fraction By Weight: 3%
OSHA PEL 100 PPM
ACGIH TLV: 100 PPM;125 STEL
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
5.9.
CAS: 1330-20-7
RTECS: ZE2100000
Fraction By Weight: 18%
OSHA PEL 100 PPM
ACGIH TLV: 100 PPM;150 STEL
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
180.
CAS: 67-64-1
RTECS: AL3150000
Fraction By Weight: 29%
OSHA PEL 1000 PPM
ACGIH TLV: 750 PPM;1000 STEL
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
PROPIONIC ACID, 3-ETHOXY-, ETHYL ESTER;
CAS: 763-69-9
RTECS: UF3325000
Fraction By Weight: 3%
OSHA PEL N/K
ACGIH TLV: N/K
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EXPOS MAY BE BY INHAL &/OR SKIN/EYE
CONT, DEPENDING ON CNDTNS OF USE. TO MIN EXPOS, FOLLOW RECS FOR
PROPER USE, VENT & PPE. ACUTE:IRRIT OF EYES, SKIN & RESP SYS. MAY
CAUSE NERV SYS DEPRESS. EXTREME OV EREXP MAY RSLT IN UNCON & POSS
DEATH. HDCH, DIZZ, NAUS & LOSS OF COORD ARE INDICATIONS OF
EXCESSIVE (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:EXPOS TO VAPS/SPRAY MISTS. REDNESS &
ITCH/BURNING SENSATION MAY INDICATE EYE/EXCESSIVE SKIN EXPOS.
CHRONIC:PRLNG OVEREXP TO SOLVS INGS MAY CAUSE ADVERSE EFTS TO
LIVER, URINARY, CVS & REPRO SY S. RPTS HAVE ASSOC RPTD & PRLNG
OVEREXPTO SOLVS W/PERM BRAIN & NERV SYS DMG. INTENTIONAL MISUSE BY
DELIB CONC &(ING 10)
Medical Cond Aggravated by Exposure:NONE GENERALLY RECOGNIZED.
First Aid
First Aid:INHAL:REMOVE FROM EXPOSURE. RESTORE BREATHING. KEEP WARM &
QUIET. SKIN:WASH AFFECTED AREA THOROUGHLY W/SOAP & WATER. REMOVE
CONTAMINATED CLOTHING & LAUNDER BEFORE RE-USE. EYES:FLUSH W/LARGE
AMOUNTS OF WATER FOR AT LEAST 15 MINUTES. GET MEDICAL ATTENTION.
INGEST:SEEK MEDICAL ATTENTION.
Fire Fighting
Flash Point Method:PMCC
Flash Point:<0F,<-18C
Lower Limits:0.7%
Upper Limits:12.8%
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, FOAM.
Fire Fighting Procedures:USE NIOSH APPRVD SCBA & FULL PROT EQUIP .
WATER SPRAY MAY BE INEFT. IF WATER IS USED, FOG NOZZ ARE PREF.
WATER MAY BE USED TO COOL CLSD CNTNRS TO (SUPDAT)
Unusual Fire/Explosion Hazard:EXTREMELY FLAMM. ISOLATE FROM HEAT, ELEC
EQUIP, SPKS & OPEN FLAME. CLSD CNTNRS MAY EXPLODE WHEN EXPOS TO
EXTREME HEAT. APPLICATION TO HOT SURFS REQS (SUPP DATA)
Accidental Release
Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION. VENTILATE &
REMOVE W/INERT ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:DOL STORAGE CATEGORY-1A. CONTENTS ARE
EXTREMELY FLAMM. KEEP AWAY FROM HEAT, SPKS & OPEN FLAME. VAPS WILL
ACCUM READILY & MAY IGNITE EXPLOSIVELY.
Other Precautions:DURING USE & UNTIL ALL VAPS ARE GONE:KEEP AREA
VENTED; DO NOT SMOKE; EXTING ALL FLAMES, PILOT LIGHTS & HEATERS;
TURN OFF STOVES, ELEC TOOLS & APPLIANCES & ANY OTHER SOURCES OF
IGNIT. CONSULT NFPA CODE . USE APPRVD BONDING & GROUNDING(ING 14)
Exposure Controls
Respiratory Protection:IF PERSONAL EXPOS CANNOT BE CONTROLLED BELOW
APPLIC LIMS BY VENT, WEAR A PROPERLY FITTED NIOSH APPRVD ORG
VAP/PARTICULATE RESP FOR PROT AGAINST INGS. WHEN SANDING/ABRADING
DRIED FILM, WEAR A NIOSH APP RVD DUST/MIST RESP FOR PROT (SUPP
DATA)
Ventilation:LOC EXHST PREF. GEN EXHST ACCEPT IF EXPOS TO INGS IS
MAINTAINED BELOW APPLIC EXPOS LIMS. REFER TO OSHA STDS (SUPP DATA)
Protective Gloves:CHEMICAL RESISTANT GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA .
Work Hygienic Practices:WASH HANDS AFTER USING.
Supplemental Safety and Health
MFR'S TRADE NAME/PART NO:CONTROLS RUST SPRAY ENAMEL. FIRE FIGHT
PROC:PVNT PRESS BUILD-UP & POSS AUTOIGNIT/EXPLO WHEN EXPOS TO
EXTREME HEAT. RESP PROT:AGAINST NON-VOLAT INGS. VENT:1910.94,
1910.107, 19 10.108. EXPLO HAZ:SPECIAL PRECS. DURINGEMER CNDTNS
OVEREXP TO DECOMP PRODS MAY CAUSE HLTH HAZ. SYMPS MAY NOT BE (ING
9)
Chemical Properties
Boiling Pt:B.P. Text:<342F,<172C
Vapor Pres:SEE INGS
Vapor Density:HVR/AIR
Volatile Org Content %:85
Evaporation Rate & Reference:FASTER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Stability
Stability Indicator/Materials to Avoid:YES
NONE KNOWN.
Stability Condition to Avoid:NONE KNOWN.
Hazardous Decomposition Products:BY FIRE: CARBON DIOXIDE, CARBON
MONOXIDE.
Disposal
Waste Disposal Methods:WASTE FROM THIS PROD MAY BE HAZ AS DEFINED UNDER
THE RCRA (40 CFR 261). WASTE MUST BE TESTED FOR IGNITABILITY TO
DETERMINE APPLIC EPA HAZ WASTE NUMBER. DO NOT INCIN. DEPRESSURIZE
CNTNR. DISP OF I/A/W FED, STATE & LOC REGS REGARDING POLLUTION.
Other Information
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.